Most renovation regrets are small and sit at hand height: a socket hidden behind the new fridge, a switch across the room from the door, one point too few beside the bed. A modular switch board is easy to choose and hard to move once tiles and paint are done. A simple map drawn before the walls are chased avoids almost all of it.
This guide shows how to plan switch and socket positions room by room, count modules and leave room for future needs.
Quick Answer: To plan a modular switch board, list every light control and appliance room by room, mark positions on your furniture layout, count the modules each board needs and add spares. Place boards where hands naturally reach, keep sockets close to the appliance, and have a licensed electrician confirm circuits and ratings before walls are chased.
Because switch boards sit behind the finish. Conduits are concealed before plaster, tiles and carpentry, so a missed point later means breaking a finished wall. In a draft revision of its residential electrical layout guide, circulated for comment in September 2024, the Bureau of Indian Standards advises architect, electrician and owner to exchange requirements before drawings are made. It notes that later additions often lead to substandard work. The guide is still a draft, but the advice is practical. Share your furniture layout and appliance list with your electrician before any point is marked.
Work room by room, with switches near the door and sockets near the appliance. The BIS draft places general light and fan boards close to the door frame on the side opposite the hinge, at an average height of about 1.3 m. Appliance sockets should sit as close to the appliance as possible. Lower-level sockets should be 300 mm above the finished floor and shuttered. Bedrooms need two-way control near the door and beside the bed, and wet-area switches belong outside the splash zone.
| Room | What to plan | Hosper options to consider |
| Living room | Door board for lights and fans, TV and charging points, AC point | Elena, Slim or Flat plates; USB socket |
| Bedroom | Two-way light and fan at door and bedside, charging, AC | Lifestyle switches; 4-step regulator |
| Kitchen | Counter sockets, heavy-appliance points | 16 A shuttered socket |
| Bathroom | Switch outside wet zone, geyser on its own circuit | 32 A double-pole switch, as your electrician specifies |
Put outlets at least 150 mm above the platform, beside the appliance and not behind it, and well away from heat sources. That is the BIS draft’s advice for kitchens. The same draft says any kitchen appliance rated 2 kW or above needs an independent circuit, and no power circuit should carry more than two 16 A points or 3,000 W. Its sample loads include induction at 2,000 W, microwave at 2,000 W, air fryer at 1,500 W and toaster or kettle at 800 W. Plan a shuttered 16 A socket for each heavy appliance.
Count function by function, then choose the plate. List every switch, socket, regulator and USB point for the board, and note how many modules each takes. On Hosper’s product pages, the 4-step regulator and USB socket are 1M each, while the 16 A shuttered socket and 32 A double-pole switch are 2M each. A board with a regulator, USB socket and 16 A socket already needs four modules before any switches. Total the modules, pick a plate that holds them with one or two spare, and check capacity on the modular plates page. The BIS draft also suggests a 6 A socket on lighting boards, so neutral and earth are available for future additions.
Plan for appliances you may add, not only those you own today. The BIS draft lists independent circuits for air-conditioners, water heaters, kitchen appliances of 2 kW or more, washing machines of 2 kW or more, water pumps and EV charging. It suggests a separate circuit for inverter-backed points and, in anticipation of later additions, cable one size higher than the minimum. Even if the AC arrives next year, ask your electrician to run its point and circuit now. Adding one after plastering costs far more than planning it today.
A licensed electrician should confirm circuits, protection and earthing before walls are chased. Ask which MCBs and 30 mA RCDs the plan uses, and look for the ISI mark on switches and sockets. The BIS draft’s reference list names IS 3854 for switches and IS 1293 for plugs and sockets. Hosper’s BIS/ISI guide explains how to check a licence number. For distribution boards, see the MCB and DB range.
How many switches and sockets does a room need?
It depends on room size and appliances. The BIS draft sets minimum points per 10 to 12 m² and calls them a bare minimum. Add points for your furniture layout and ask your electrician to confirm.
What height should a modular switch board be?
The BIS draft suggests about 1.3 m for light and fan boards. Lower sockets go 300 mm above the floor and must be shuttered. Confirm with your electrician.
Do kitchen appliances need separate circuits?
The BIS draft recommends an independent circuit for each kitchen appliance rated 2 kW or above. Your electrician should confirm ratings and protection for your appliances.
How many modules fit in a plate?
It depends on the plate size. Count your modules first, then check the capacity of each plate on its product page.
Can I change the switch board layout after tiling?
Yes, but it usually means breaking finished walls. Mapping every point before chasing is far cheaper.
Hosper makes modular switches, sockets, regulators and plates in several design lines, so one board can mix functions and finishes. Its FAQ lists a 10-year warranty on switches and sockets, with shorter cover for LED indicators and electronic regulators, so confirm terms with your dealer. Browse the modular range, the modular sockets and the modular regulators. Download the Hosper catalogue, or contact Hosper before you finalise your plan. Designers can start at the architects page.